Login
REGISTER
What Users Get:
Complete Your Profile
Change Password
Request a Password Reset
Home > Tenders > Supply Of Specification For Paeditric Oxygenator Priming Volume Maximum S...
Tender for Supply Of Specification For Paeditric Oxygenator Priming Volume Maximum Should Be Less Than 105Ml.Minimum Operating Volume Approx. 30 Ml O Maximum Blood Flow Rate Should Be 2.8.Ltrs/Min. O... from Madhya Pradesh. The reference number of the tender is: 111587549 and the same is closing on 6th Jan 2025. Users can register on the site to get similar tenders.
Procurement Summary
Country : India
State : Madhya Pradesh
Summary : Supply Of Specification For Paeditric Oxygenator Priming Volume Maximum Should Be Less Than 105Ml.Minimum Operating Volume Approx. 30 Ml O Maximum Blood Flow Rate Should Be 2.8.Ltrs/Min. O...
Deadline : 06 Jan 2025
Purchaser's Detail
Other Information
Notice Type : Tender
RefID : 111587549
Notice Ref. No. :
Tender Value : Refer Document
Tender EMD : ₹ 50000
Tender Document Cost : Refer Document
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender's Details
Tenders Are Invited For Supply Of Specification For Paeditric Oxygenator Priming Volume Maximum Should Be Less Than 105Ml.Minimum Operating Volume Approx. 30 Ml O Maximum Blood Flow Rate Should Be 2.8.Ltrs/Min. O Oxygen Transfer Should Not Be Less Than 250Ml/Min.O Pressure Drop Should Be Least-Up To 100Mmhg Or Less.O Heat Exchange Efficiency Should Not Be Less Than 0.65. Surface Area Of The Fibers Should Be Approx0.8 To 1.0M2 . O Heat Exchanger Fibre Material Shouldbe Made Of Polyurethane [Tpu] And Surface Area Should Be Approx. 0.13M2 To 0.15M2 . Blood Inlet Port 3/8 Blood Outlet Port 1/4 Cardioplegia Port 1/4 Gas Inlet Port 1/4 Gas Outlet Port 1/4Water Port 1/2 Maximum Pressure Blood Inlet 1000Mmhg, Water Inlet 42 Psi O Blood Storage Capacity Of Hard Shell Reservoir Should Be Max 3000Ml.O Minimum Operative Volume Of Hard Shell Reservoir Should Be 100Ml. At Jabalpur
Emd:50, 000
Tender Fee:1000
Supply Of Specification For Paeditric Oxygenator Priming Volume Maximum Should Be Less Than 105Ml.Minimum Operating Volume Approx. 30 Ml O Maximum Blood Flow Rate Should Be 2.8.Ltrs/Min. O Oxygen Transfer Should Not Be Less Than 250Ml/Min.O Pressure Drop Should Be Least-Up To 100Mmhg Or Less.O Heat Exchange Efficiency Should Not Be Less Than 0.65. Surface Area Of The Fibers Should Be Approx0.8 To 1.0M2 . O Heat Exchanger Fibre Material Shouldbe Made Of Polyurethane [Tpu] And Surface Area Should Be Approx. 0.13M2 To 0.15M2 . Blood Inlet Port 3/8 Blood Outlet Port 1/4 Cardioplegia Port 1/4 Gas Inlet Port 1/4 Gas Outlet Port 1/4Water Port 1/2 Maximum Pressure Blood Inlet 1000Mmhg, Water Inlet 42 Psi O Blood Storage Capacity Of Hard Shell Reservoir Should Be Max 3000Ml.O Minimum Operative Volume Of Hard Shell Reservoir Should Be 100Ml. At Jabalpur
Notice Documents
Get Local Agent Support for this Tenders.
ContactUs1 State
Rs. 2500 + GST
Unlimited Website Access
Unlimited Tenders Download
Unlimited Keyword Search
Access to Archive Tenders
Number of Accounts-1
Dedicated Key Account Manager
24*7 Customer Support
Validity-12 Months
5 States
Rs. 5000 + GST
Unlimited Website Access
Unlimited Tenders Download
Unlimited Keyword Search
Access to Archive Tenders
Number of Accounts-2
Dedicated Key Account Manager
24*7 Customer Support
Validity-12 Months
All India
Rs. 9000 + GST
Unlimited Website Access
Unlimited Tenders Download
Unlimited Keyword Search
Access to Archive Tenders
Number of Accounts-3
Dedicated Key Account Manager
24*7 Customer Support
Validity-12 Months
Browse Tenders from below Sections